This alternate compliance method was adopted DEC-122019 as an amendment to the 2018 BC Building - Code. Building Code removed previous constraints on the size of a secondary suite. Floor Area & Ceiling Heights The secondary suite must be less than 90 m˙ (968 ft˙) in Part 9 – Housing and Small Buildings Division B: Acceptable Solutions Division B Revision 2.01 British Columbia Building Code 2018 9.8.3. It is now at the discretion of each municipality. NEW: BC Building Code Amendment April 18, 2018: Passive ventilation supply air is permitted for secondary suites in residential buildings designed to BC Energy Step Code Requirements. BUILDING CODE SUMMARY This is a brief overview of the some of the minimum health and safety requirements for secondary suites outlined in Section 9.36 of the B.C. One question Coun. Stair Configurations 9.8.3.1. 1) Except as provided by Sentence (2), stairs in buildings other than dwelling units and houses with a secondary suite including their common spaces shall consist of Requirements for the construction of Secondary Suites are found throughout the provisions of Part 9. Tara Ney had was about the size of the suites. One question Coun. The change will give local governments the choice to allow secondary suites in side-by-side multi-family buildings such as duplexes, townhouses and row housing. These changes will be effective December 12, 2019, and apply to building permits applied for on or after this date. units apply to the installation of a secondary suite in an Refer to our existing dwelling unit.companion guide, Secondary Suites - Building Code and Zoning Requirements, for more information. This information must be shown on the submitted plans. (See Note A-9.32.3.1.(1).) British Columbia Building Code 2018 Revision 2.01 Division B c) for ducted mechanical ventilation systems serving more than one dwelling unit in a house with a secondary suite including their common spaces, the mechanical ventilation system shall comply with this Subsection or Part 6. It is now at the discretion of each municipality. Revision 2 of the 2018 BCBC removed 9.37 from the BCBC effective December 12, 2019. Tara Ney had was about the size of the suites. Not be subdivided from the building it is part of under the Strata Act; and, Building Code (2006). building code address secondary suites, energy efficiency ... on Monday December 10, 2018. Secondary Suites are no longer specifically regulated under Section 9.37 of the 2018 British Columbia Building Code (BCBC). 9.32.3.2. The B.C. Permitted Configurations (See Note A-9.8.4.) Changes to B.C. The British Columbia government has announced changes to the building code that expand options for secondary suites in multi-family buildings. Be located within a building in compliance with the latest Zoning Bylaw #5000. The British Columbia government has announced changes to the building code that expand options for secondary suites in multi-family buildings. SECONDARY SUITE BUILDING CODE REQUIREMENTS MEANING OF SECONDARY SUITE A secondary suite shall: Have a total floor area as required by the latest Zoning Bylaw #5000. The B.C. Nov 22, 2019 3:32 PM By: The Canadian Press Share on Facebook Design and Installation The British Columbia government has announced changes to the building code that expand options for secondary suites in multi-family buildings. Building Code removed previous constraints on the size of a secondary suite. Where a heating or ventilation duct system serves more than one suite, the system shall be designed Amendments to the BC Building Code 2018 include: Changes to harmonize the BC Building Code with the National Building Code to provide greater flexibility for the construction of new secondary suites;